Napowietrzacz przewodu 1/2'' chrom
Anti-vacuum device
Flow form, version C
For installing on appliance connection fittings with backflow preventer, without anti-vacuum device.Technical data
- Max. Operating pressure: 10 bar
- Max. operating temperature: 70 °C
- Safety device, conforms to EN 1717: HB
- Connection: DN 15 G 1/2 AG
- Outlet: DN 15 G 1/2 IG
- Material: Brass, conform to German drinking water regulations
- Surface: Chrome
- Certificates: DIN-DVGW
Note
- Together with appliance connection fittings with backflow preventer HP safety combination (EN 1717).
Mounting instruction
- Downstream pipework must be flexible and removable.
- The tube diffuser must be installed vertically and be fully accessible.
- Tube diffusers must not be installed in rooms at risk of flooding.
- The tube diffuser must be installed in a ventilated environment (clean atmosphere) and protected against frost/high temperatures.
- No shut-off device may be installed downstream of the tube diffuser.
- The minimum distance to the subsequent liquid level must be > 250 mm.
- Tube diffusers must not be exposed to constant back pressure.
From bathrooms to kitchens, and cellars to garages and gardens, the focus should always be on the safe handling of water. This is where appliance connection fittings from SCHELL help out. Whatever the valve needed, in new buildings or renovation projects, the SCHELL product portfolio always has the right model – and, naturally, always with the trusted SCHELL quality and materials safe to use with drinking water.
Note
- Together with appliance connection fittings with backflow preventer HP safety combination (EN 1717).
Mounting instruction
- Downstream pipework must be flexible and removable.
- The tube diffuser must be installed vertically and be fully accessible.
- Tube diffusers must not be installed in rooms at risk of flooding.
- The tube diffuser must be installed in a ventilated environment (clean atmosphere) and protected against frost/high temperatures.
- No shut-off device may be installed downstream of the tube diffuser.
- The minimum distance to the subsequent liquid level must be > 250 mm.
- Tube diffusers must not be exposed to constant back pressure.
Dane produktu
| Grupa produktowa | Safety fittings |
|---|---|
| Grupa towarowa | Appliance connections |
| Kraj pochodzenia | DE |